Name: PuestoProteccionDinamico
Display Field: USUARIOREGISTRO
Type: Feature Layer
Geometry Type: esriGeometryPoint
Description:
Service Item Id: ca836189b1b54b31961c879c936886ec
Copyright Text:
Default Visibility: true
MaxRecordCount: 2000
Supported Query Formats: JSON, geoJSON, PBF
Min Scale: 0
Max Scale: 0
Supports Advanced Queries: true
Supports Statistics: true
Has Labels: false
Can Modify Layer: true
Can Scale Symbols: false
Use Standardized Queries: true
Supports Datum Transformation: true
Extent:
XMin: 609202.871875
YMin: 9552071.453125
XMax: 1245880.96875
YMax: 1.018874955E7
Spatial Reference: 32717
(32717)
Drawing Info:
Renderer:
Simple Renderer:
Symbol: Style: esriSMSCircle
Color:
[140, 138, 0, 255]
Size: 4.0
Angle: 0.0
XOffset: 0
YOffset: 0
Outline:
Label: N/A
Description: N/A
Transparency: 0
Labeling Info:
Advanced Query Capabilities:
Supports Statistics: true
Supports OrderBy: true
Supports Distinct: true
Supports Pagination: false
Supports TrueCurve: true
Supports Returning Query Extent: true
Supports Query With Distance: true
Supports Sql Expression: true
Supports Query With ResultType: false
Supports Returning Geometry Centroid: false
HasZ: false
HasM: false
Has Attachments: false
HTML Popup Type: esriServerHTMLPopupTypeAsHTMLText
Type ID Field: Subtipo
Fields:
-
OBJECTID
(
type: esriFieldTypeOID, alias: OBJECTID
)
-
ANCILLARYROLE
(
type: esriFieldTypeSmallInteger, alias: ANCILLARY ROLE
,
Coded Values:
[0: None]
,
[1: Source]
,
[2: Sink]
)
-
ENABLED
(
type: esriFieldTypeSmallInteger, alias: ENABLED
,
Coded Values:
[0: False]
,
[1: True]
)
-
USUARIOREGISTRO
(
type: esriFieldTypeString, alias: Usu Cre, length: 50
)
-
FECHAREGISTRO
(
type: esriFieldTypeDate, alias: F Cre Sis, length: 8
)
-
FECHAMODIFICACIONREGISTRO
(
type: esriFieldTypeDate, alias: F Mod Sis, length: 8
)
-
USUARIOMODIFICACIONREGISTRO
(
type: esriFieldTypeString, alias: Usu Mod, length: 50
)
-
ELECTRICTRACEWEIGHT
(
type: esriFieldTypeInteger, alias: Electric Trace Weight
)
-
ALIMENTADORID
(
type: esriFieldTypeString, alias: Alim1, length: 10
,
Coded Values:
[0100020T04: PILISHURCO]
,
[0100030T01: PENINSULA]
,
[0100030T02: IZAMBA]
, ...114 more...
)
-
ALIMENTADOR2ID
(
type: esriFieldTypeString, alias: Alim2, length: 10
,
Coded Values:
[0100020T04: PILISHURCO]
,
[0100030T01: PENINSULA]
,
[0100030T02: IZAMBA]
, ...114 more...
)
-
ALIMENTADORINFO
(
type: esriFieldTypeInteger, alias: Inform Alim
)
-
PROYECTOCONSTRUCCION
(
type: esriFieldTypeString, alias: Proyecto Const, length: 32
)
-
FECHACONSTRUCCION
(
type: esriFieldTypeDate, alias: F Construccion, length: 8
)
-
FECHAACTIVACION
(
type: esriFieldTypeDate, alias: FECHAENERGIZACION, length: 8
)
-
PROYECTOMODIFICACION
(
type: esriFieldTypeString, alias: FINANCIAMIENTO, length: 32
)
-
CODIGOEMPRESA
(
type: esriFieldTypeString, alias: Codigo Empresa, length: 10
,
Coded Values:
[CNELMANABI: CNELEP-MANABI]
,
[CNELELORO: CNELEP-EL ORO]
,
[CNELSTODGO: CNELEP-SANTO DOMINGO]
, ...17 more...
)
-
PROVINCIA
(
type: esriFieldTypeString, alias: Provincia, length: 2
,
Coded Values:
[01: AZUAY]
,
[02: BOLIVAR]
,
[03: CANAR]
, ...22 more...
)
-
CANTON
(
type: esriFieldTypeString, alias: Canton, length: 4
,
Coded Values:
[0101: CUENCA]
,
[0102: GIRON]
,
[0103: GUALACEO]
, ...221 more...
)
-
SUBTIPO
(
type: esriFieldTypeInteger, alias: SUBTIPO
)
-
CODIGOPUESTO
(
type: esriFieldTypeString, alias: Codigo Puesto, length: 20
)
-
TEXTOETIQUETA
(
type: esriFieldTypeString, alias: Etiqueta, length: 255
)
-
FASECONEXION
(
type: esriFieldTypeInteger, alias: Fase Conexion
,
Coded Values:
[4: A]
,
[2: B]
,
[1: C]
, ...4 more...
)
-
VOLTAJE
(
type: esriFieldTypeInteger, alias: Voltaje
,
Coded Values:
[500000: 500 kV]
,
[230000: 230 kV]
,
[138000: 138 kV]
, ...16 more...
)
-
COMENTARIOS
(
type: esriFieldTypeString, alias: COMENTARIOS, length: 255
)
-
HIPERVINCULO
(
type: esriFieldTypeString, alias: HIPERVINCULO, length: 255
)
-
POSICIONNORMAL_A
(
type: esriFieldTypeInteger, alias: Posicion Normal A
,
Coded Values:
[0: Abierto]
,
[1: Cerrado]
,
[2: No Aplicable]
)
-
POSICIONNORMAL_B
(
type: esriFieldTypeInteger, alias: Posicion Normal B
,
Coded Values:
[0: Abierto]
,
[1: Cerrado]
,
[2: No Aplicable]
)
-
POSICIONNORMAL_C
(
type: esriFieldTypeInteger, alias: Posicion Normal C
,
Coded Values:
[0: Abierto]
,
[1: Cerrado]
,
[2: No Aplicable]
)
-
POSICIONACTUAL_A
(
type: esriFieldTypeInteger, alias: Posicion Actual A
,
Coded Values:
[0: Abierto]
,
[1: Cerrado]
,
[2: No Aplicable]
)
-
POSICIONACTUAL_B
(
type: esriFieldTypeInteger, alias: Posicion Actual B
,
Coded Values:
[0: Abierto]
,
[1: Cerrado]
,
[2: No Aplicable]
)
-
POSICIONACTUAL_C
(
type: esriFieldTypeInteger, alias: Posicion Actual C
,
Coded Values:
[0: Abierto]
,
[1: Cerrado]
,
[2: No Aplicable]
)
-
INTERRUPTORBYPASS
(
type: esriFieldTypeString, alias: Interruptor By Pass, length: 1
,
Coded Values:
[N: No]
,
[S: Si]
)
-
INDICADORPOSICIONINTERRUPTOR
(
type: esriFieldTypeInteger, alias: Posis Interr
,
Coded Values:
[0: Abierto]
,
[1: Cerrado]
,
[2: No Aplicable]
)
-
ESTRUCTURASOPORTEOBJECTID
(
type: esriFieldTypeInteger, alias: Estructura Soporte OID
)
-
ESTRUCTURANIVELOBJECTID
(
type: esriFieldTypeInteger, alias: Estructura Nivel OID
)
-
ROTACIONSIMBOLO
(
type: esriFieldTypeDouble, alias: ROTACIONSIMBOLO
)
-
MISUBTIPO
(
type: esriFieldTypeSmallInteger, alias: MISUBTIPO
)
-
PARROQUIA
(
type: esriFieldTypeString, alias: Parroquia, length: 6
,
Coded Values:
[010101: BELLAVISTA]
,
[010102: CAÑARIBAMBA]
,
[010103: EL BATÁN]
, ...1407 more...
)
-
KVLN
(
type: esriFieldTypeDouble, alias: KVLN
)
-
CORRIENTE
(
type: esriFieldTypeDouble, alias: Corriente
,
Coded Values:
[50: 50 A]
,
[100: 100 A]
,
[200: 200 A]
, ...12 more...
)
-
CAIDA_TENSION_ACUM
(
type: esriFieldTypeDouble, alias: Caida de Tension Acumulada
)
-
CORRIENTE_3F_CIRCUITO
(
type: esriFieldTypeDouble, alias: Corriente TriFas.Cortocircuito
)
-
DEMANDA
(
type: esriFieldTypeDouble, alias: Demanda
)
-
POSICION
(
type: esriFieldTypeSmallInteger, alias: Posición
)
-
PROTECCION
(
type: esriFieldTypeString, alias: Protección, length: 1
,
Coded Values:
[N: No]
,
[S: Si]
)
-
CAPACIDADEQUIPO
(
type: esriFieldTypeDouble, alias: Capacidad Equipo
)
-
CORRIENTE_1F_CIRCUITO
(
type: esriFieldTypeDouble, alias: Corriente MonoFas.Cortocircuito
)
-
POTENCIA_ACUMULADA
(
type: esriFieldTypeDouble, alias: Potencia Acumulada
)
-
INDICE_FALLAS
(
type: esriFieldTypeDouble, alias: Indice de Fallas
)
-
CLIENTES_ACUMULADOS
(
type: esriFieldTypeDouble, alias: Clientes Acumulados
)
-
CODIGOESTRUCTURA
(
type: esriFieldTypeString, alias: Codigo Estructura, length: 10
)
-
MIOID
(
type: esriFieldTypeInteger, alias: MIOID
)
-
GLOBALID
(
type: esriFieldTypeGlobalID, alias: GLOBALID, length: 38
)
-
ESTRUCTURANIVELGLOBALID
(
type: esriFieldTypeGUID, alias: EstructuraNivelGLOBALID, length: 38
)
-
ESTRUCTURASOPORTEGLOBALID
(
type: esriFieldTypeGUID, alias: EstructuraSoporteGLOBALID, length: 38
)
-
PARENTCIRCUITSOURCEGUID
(
type: esriFieldTypeGUID, alias: ParentCircuitSourceGUID, length: 38
)
-
CIRCUITSOURCEGUID
(
type: esriFieldTypeGUID, alias: CircuitSourceGUID, length: 38
)
-
SUBSOURCE
(
type: esriFieldTypeSmallInteger, alias: SubSource
,
Coded Values:
[1: Si]
,
[0: No]
)
-
ALIMENTADOR
(
type: esriFieldTypeString, alias: Nombre Alimentador, length: 10
)
-
MIGUID
(
type: esriFieldTypeGUID, alias: MIGUID, length: 38
)
-
CORRIENTEMAXCORTOCIRCUITO
(
type: esriFieldTypeInteger, alias: Corriente max. Apertura
,
Coded Values:
[2500: 2.5 kA]
,
[4000: 4 kA]
,
[6000: 6 kA]
, ...11 more...
)
-
OBSERVACIONES
(
type: esriFieldTypeString, alias: Observaciones, length: 255
)
-
ALIMENTADOR2
(
type: esriFieldTypeString, alias: Nombre Alimentador 2, length: 10
)
-
SHAPE
(
type: esriFieldTypeGeometry, alias: Shape
)
-
TRANSFERENCIAACTIVO
(
type: esriFieldTypeString, alias: TRANSFERENCIAACTIVO, length: 2
,
Coded Values:
[N: No]
,
[S: Si]
)
-
CODIGOADMS
(
type: esriFieldTypeString, alias: CODIGOADMS, length: 100
)
-
TIPOUSO
(
type: esriFieldTypeString, alias: TIPOUSO, length: 30
,
Coded Values:
[Cabecera Alimentador: Cabecera Alimentador]
,
[Celda: Celda]
,
[Línea: Línea]
, ...1 more...
)
-
CONTROL
(
type: esriFieldTypeString, alias: CONTROL, length: 30
,
Coded Values:
[Manual: Manual]
,
[Telecomandado: Telecomandado]
)
-
ORDENTRABAJO
(
type: esriFieldTypeString, alias: ORDENTRABAJO, length: 50
)
-
FACILITYID
(
type: esriFieldTypeString, alias: FACILITYID, length: 10
)
Types:
ID: 1
Name: Disyuntor
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
ALIMENTADORID:
Inherited
-
ALIMENTADOR2ID:
Inherited
-
CODIGOEMPRESA:
Inherited
-
PROVINCIA:
Inherited
-
CANTON:
Inherited
-
FASECONEXION:
Inherited
-
VOLTAJE:
Inherited
-
POSICIONNORMAL_A:
Inherited
-
POSICIONNORMAL_B:
Inherited
-
POSICIONNORMAL_C:
Inherited
-
POSICIONACTUAL_A:
Inherited
-
POSICIONACTUAL_B:
Inherited
-
POSICIONACTUAL_C:
Inherited
-
INTERRUPTORBYPASS:
Inherited
-
INDICADORPOSICIONINTERRUPTOR:
Inherited
-
PARROQUIA:
Inherited
-
CORRIENTE:
Inherited
-
PROTECCION:
Inherited
-
CODIGOESTRUCTURA:
Coded Values:
[SPR0013: 1I100_95R]
,
[SPR0014: 1I100_125R]
,
[SPR0070: 1I100_150R]
, ...149 more...
-
SUBSOURCE:
Inherited
-
CORRIENTEMAXCORTOCIRCUITO:
Inherited
-
TRANSFERENCIAACTIVO:
Inherited
-
TIPOUSO:
Inherited
-
CONTROL:
Inherited
ID: 3
Name: Interruptor
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
ALIMENTADORID:
Inherited
-
ALIMENTADOR2ID:
Inherited
-
CODIGOEMPRESA:
Inherited
-
PROVINCIA:
Inherited
-
CANTON:
Inherited
-
FASECONEXION:
Inherited
-
VOLTAJE:
Inherited
-
POSICIONNORMAL_A:
Inherited
-
POSICIONNORMAL_B:
Inherited
-
POSICIONNORMAL_C:
Inherited
-
POSICIONACTUAL_A:
Inherited
-
POSICIONACTUAL_B:
Inherited
-
POSICIONACTUAL_C:
Inherited
-
INTERRUPTORBYPASS:
Inherited
-
INDICADORPOSICIONINTERRUPTOR:
Inherited
-
PARROQUIA:
Inherited
-
CORRIENTE:
Inherited
-
PROTECCION:
Inherited
-
CODIGOESTRUCTURA:
Coded Values:
[SPR0013: 1I100_95R]
,
[SPR0014: 1I100_125R]
,
[SPR0070: 1I100_150R]
, ...148 more...
-
CORRIENTEMAXCORTOCIRCUITO:
Inherited
-
TRANSFERENCIAACTIVO:
Inherited
-
TIPOUSO:
Inherited
-
CONTROL:
Inherited
ID: 2
Name: Seccionalizador
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
ALIMENTADORID:
Inherited
-
ALIMENTADOR2ID:
Inherited
-
CODIGOEMPRESA:
Inherited
-
PROVINCIA:
Inherited
-
CANTON:
Inherited
-
FASECONEXION:
Inherited
-
VOLTAJE:
Inherited
-
POSICIONNORMAL_A:
Inherited
-
POSICIONNORMAL_B:
Inherited
-
POSICIONNORMAL_C:
Inherited
-
POSICIONACTUAL_A:
Inherited
-
POSICIONACTUAL_B:
Inherited
-
POSICIONACTUAL_C:
Inherited
-
INTERRUPTORBYPASS:
Inherited
-
INDICADORPOSICIONINTERRUPTOR:
Inherited
-
PARROQUIA:
Inherited
-
CORRIENTE:
Inherited
-
PROTECCION:
Inherited
-
CODIGOESTRUCTURA:
Coded Values:
[SPR0017: 1R400_95R]
,
[SPR0018: 1R400_125R]
,
[SPR0019: 1R600_95R]
, ...116 more...
-
SUBSOURCE:
Inherited
-
CORRIENTEMAXCORTOCIRCUITO:
Inherited
-
TRANSFERENCIAACTIVO:
Inherited
-
TIPOUSO:
Inherited
-
CONTROL:
Inherited
ID: 4
Name: Reconectador
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
ALIMENTADORID:
Inherited
-
ALIMENTADOR2ID:
Inherited
-
CODIGOEMPRESA:
Inherited
-
PROVINCIA:
Inherited
-
CANTON:
Inherited
-
FASECONEXION:
Inherited
-
VOLTAJE:
Inherited
-
POSICIONNORMAL_A:
Inherited
-
POSICIONNORMAL_B:
Inherited
-
POSICIONNORMAL_C:
Inherited
-
POSICIONACTUAL_A:
Inherited
-
POSICIONACTUAL_B:
Inherited
-
POSICIONACTUAL_C:
Inherited
-
INTERRUPTORBYPASS:
Inherited
-
INDICADORPOSICIONINTERRUPTOR:
Inherited
-
PARROQUIA:
Inherited
-
CORRIENTE:
Inherited
-
PROTECCION:
Inherited
-
CODIGOESTRUCTURA:
Coded Values:
[SPR0017: 1R400_95R]
,
[SPR0018: 1R400_125R]
,
[SPR0019: 1R600_95R]
, ...115 more...
-
CORRIENTEMAXCORTOCIRCUITO:
Inherited
-
TRANSFERENCIAACTIVO:
Inherited
-
TIPOUSO:
Inherited
-
CONTROL:
Inherited
ID: 5
Name: Celdas de Seccionamiento
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
ALIMENTADORID:
Inherited
-
ALIMENTADOR2ID:
Inherited
-
CODIGOEMPRESA:
Inherited
-
PROVINCIA:
Inherited
-
CANTON:
Inherited
-
FASECONEXION:
Inherited
-
VOLTAJE:
Inherited
-
POSICIONNORMAL_A:
Inherited
-
POSICIONNORMAL_B:
Inherited
-
POSICIONNORMAL_C:
Inherited
-
POSICIONACTUAL_A:
Inherited
-
POSICIONACTUAL_B:
Inherited
-
POSICIONACTUAL_C:
Inherited
-
INTERRUPTORBYPASS:
Inherited
-
INDICADORPOSICIONINTERRUPTOR:
Inherited
-
PARROQUIA:
Inherited
-
CORRIENTE:
Inherited
-
PROTECCION:
Inherited
-
CODIGOESTRUCTURA:
Coded Values:
[SSS0067: 3ES600_150S]
,
[SST0067: 3ES600_150T]
,
[SSV0067: 3ES600_150V]
-
SUBSOURCE:
Inherited
-
CORRIENTEMAXCORTOCIRCUITO:
Inherited
-
TRANSFERENCIAACTIVO:
Inherited
-
TIPOUSO:
Inherited
-
CONTROL:
Inherited
ID: 6
Name: Celdas de Interconexión
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
ALIMENTADORID:
Inherited
-
ALIMENTADOR2ID:
Inherited
-
CODIGOEMPRESA:
Inherited
-
PROVINCIA:
Inherited
-
CANTON:
Inherited
-
FASECONEXION:
Inherited
-
VOLTAJE:
Inherited
-
POSICIONNORMAL_A:
Inherited
-
POSICIONNORMAL_B:
Inherited
-
POSICIONNORMAL_C:
Inherited
-
POSICIONACTUAL_A:
Inherited
-
POSICIONACTUAL_B:
Inherited
-
POSICIONACTUAL_C:
Inherited
-
INTERRUPTORBYPASS:
Inherited
-
INDICADORPOSICIONINTERRUPTOR:
Inherited
-
PARROQUIA:
Inherited
-
CORRIENTE:
Inherited
-
PROTECCION:
Inherited
-
CODIGOESTRUCTURA:
Coded Values:
[SSS0069: 3EI600_150S]
,
[SST0069: 3EI600_150T]
,
[SSV0069: 3EI600_150V]
-
SUBSOURCE:
Inherited
-
CORRIENTEMAXCORTOCIRCUITO:
Inherited
-
TRANSFERENCIAACTIVO:
Inherited
-
TIPOUSO:
Inherited
-
CONTROL:
Inherited
ID: 7
Name: Celdas de Protección
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
ALIMENTADORID:
Inherited
-
ALIMENTADOR2ID:
Inherited
-
CODIGOEMPRESA:
Inherited
-
PROVINCIA:
Inherited
-
CANTON:
Inherited
-
FASECONEXION:
Inherited
-
VOLTAJE:
Inherited
-
POSICIONNORMAL_A:
Inherited
-
POSICIONNORMAL_B:
Inherited
-
POSICIONNORMAL_C:
Inherited
-
POSICIONACTUAL_A:
Inherited
-
POSICIONACTUAL_B:
Inherited
-
POSICIONACTUAL_C:
Inherited
-
INTERRUPTORBYPASS:
Inherited
-
INDICADORPOSICIONINTERRUPTOR:
Inherited
-
PARROQUIA:
Inherited
-
CORRIENTE:
Inherited
-
PROTECCION:
Inherited
-
CODIGOESTRUCTURA:
Coded Values:
[SSS0068: 3EP400_150S]
,
[SST0068: 3EP400_150T]
,
[SST0076: 3EP630_95T]
, ...1 more...
-
SUBSOURCE:
Inherited
-
CORRIENTEMAXCORTOCIRCUITO:
Inherited
-
TRANSFERENCIAACTIVO:
Inherited
-
TIPOUSO:
Inherited
-
CONTROL:
Inherited
ID: 8
Name: Interruptores Subterraneos
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
ALIMENTADORID:
Inherited
-
ALIMENTADOR2ID:
Inherited
-
CODIGOEMPRESA:
Inherited
-
PROVINCIA:
Inherited
-
CANTON:
Inherited
-
FASECONEXION:
Inherited
-
VOLTAJE:
Inherited
-
POSICIONNORMAL_A:
Inherited
-
POSICIONNORMAL_B:
Inherited
-
POSICIONNORMAL_C:
Inherited
-
POSICIONACTUAL_A:
Inherited
-
POSICIONACTUAL_B:
Inherited
-
POSICIONACTUAL_C:
Inherited
-
INTERRUPTORBYPASS:
Inherited
-
INDICADORPOSICIONINTERRUPTOR:
Inherited
-
PARROQUIA:
Inherited
-
CORRIENTE:
Inherited
-
PROTECCION:
Inherited
-
CODIGOESTRUCTURA:
Coded Values:
[SSS0061: 3I4_200S]
,
[SSS0062: 3I4_600S]
,
[SSS0063: 3I4_900S]
, ...15 more...
-
SUBSOURCE:
Inherited
-
CORRIENTEMAXCORTOCIRCUITO:
Inherited
-
TRANSFERENCIAACTIVO:
Inherited
-
TIPOUSO:
Inherited
-
CONTROL:
Inherited
ID: 9
Name: Controladores-MV
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
ALIMENTADORID:
Inherited
-
ALIMENTADOR2ID:
Inherited
-
CODIGOEMPRESA:
Inherited
-
PROVINCIA:
Inherited
-
CANTON:
Inherited
-
FASECONEXION:
Inherited
-
VOLTAJE:
Inherited
-
POSICIONNORMAL_A:
Inherited
-
POSICIONNORMAL_B:
Inherited
-
POSICIONNORMAL_C:
Inherited
-
POSICIONACTUAL_A:
Inherited
-
POSICIONACTUAL_B:
Inherited
-
POSICIONACTUAL_C:
Inherited
-
INTERRUPTORBYPASS:
Inherited
-
INDICADORPOSICIONINTERRUPTOR:
Inherited
-
PARROQUIA:
Inherited
-
CORRIENTE:
Inherited
-
PROTECCION:
Inherited
-
SUBSOURCE:
Inherited
-
CORRIENTEMAXCORTOCIRCUITO:
Inherited
-
TRANSFERENCIAACTIVO:
Inherited
-
TIPOUSO:
Inherited
-
CONTROL:
Inherited
ID: 1
Name: Disyuntor
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
ALIMENTADORID:
Inherited
-
ALIMENTADOR2ID:
Inherited
-
CODIGOEMPRESA:
Inherited
-
PROVINCIA:
Inherited
-
CANTON:
Inherited
-
FASECONEXION:
Inherited
-
VOLTAJE:
Inherited
-
POSICIONNORMAL_A:
Inherited
-
POSICIONNORMAL_B:
Inherited
-
POSICIONNORMAL_C:
Inherited
-
POSICIONACTUAL_A:
Inherited
-
POSICIONACTUAL_B:
Inherited
-
POSICIONACTUAL_C:
Inherited
-
INTERRUPTORBYPASS:
Inherited
-
INDICADORPOSICIONINTERRUPTOR:
Inherited
-
PARROQUIA:
Inherited
-
CORRIENTE:
Inherited
-
PROTECCION:
Inherited
-
CODIGOESTRUCTURA:
Coded Values:
[SPR0013: 1I100_95R]
,
[SPR0014: 1I100_125R]
,
[SPR0070: 1I100_150R]
, ...149 more...
-
SUBSOURCE:
Inherited
-
CORRIENTEMAXCORTOCIRCUITO:
Inherited
-
TRANSFERENCIAACTIVO:
Inherited
-
TIPOUSO:
Inherited
-
CONTROL:
Inherited
ID: 3
Name: Interruptor
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
ALIMENTADORID:
Inherited
-
ALIMENTADOR2ID:
Inherited
-
CODIGOEMPRESA:
Inherited
-
PROVINCIA:
Inherited
-
CANTON:
Inherited
-
FASECONEXION:
Inherited
-
VOLTAJE:
Inherited
-
POSICIONNORMAL_A:
Inherited
-
POSICIONNORMAL_B:
Inherited
-
POSICIONNORMAL_C:
Inherited
-
POSICIONACTUAL_A:
Inherited
-
POSICIONACTUAL_B:
Inherited
-
POSICIONACTUAL_C:
Inherited
-
INTERRUPTORBYPASS:
Inherited
-
INDICADORPOSICIONINTERRUPTOR:
Inherited
-
PARROQUIA:
Inherited
-
CORRIENTE:
Inherited
-
PROTECCION:
Inherited
-
CODIGOESTRUCTURA:
Coded Values:
[SPR0013: 1I100_95R]
,
[SPR0014: 1I100_125R]
,
[SPR0070: 1I100_150R]
, ...148 more...
-
CORRIENTEMAXCORTOCIRCUITO:
Inherited
-
TRANSFERENCIAACTIVO:
Inherited
-
TIPOUSO:
Inherited
-
CONTROL:
Inherited
ID: 2
Name: Seccionalizador
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
ALIMENTADORID:
Inherited
-
ALIMENTADOR2ID:
Inherited
-
CODIGOEMPRESA:
Inherited
-
PROVINCIA:
Inherited
-
CANTON:
Inherited
-
FASECONEXION:
Inherited
-
VOLTAJE:
Inherited
-
POSICIONNORMAL_A:
Inherited
-
POSICIONNORMAL_B:
Inherited
-
POSICIONNORMAL_C:
Inherited
-
POSICIONACTUAL_A:
Inherited
-
POSICIONACTUAL_B:
Inherited
-
POSICIONACTUAL_C:
Inherited
-
INTERRUPTORBYPASS:
Inherited
-
INDICADORPOSICIONINTERRUPTOR:
Inherited
-
PARROQUIA:
Inherited
-
CORRIENTE:
Inherited
-
PROTECCION:
Inherited
-
CODIGOESTRUCTURA:
Coded Values:
[SPR0017: 1R400_95R]
,
[SPR0018: 1R400_125R]
,
[SPR0019: 1R600_95R]
, ...116 more...
-
SUBSOURCE:
Inherited
-
CORRIENTEMAXCORTOCIRCUITO:
Inherited
-
TRANSFERENCIAACTIVO:
Inherited
-
TIPOUSO:
Inherited
-
CONTROL:
Inherited
ID: 4
Name: Reconectador
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
ALIMENTADORID:
Inherited
-
ALIMENTADOR2ID:
Inherited
-
CODIGOEMPRESA:
Inherited
-
PROVINCIA:
Inherited
-
CANTON:
Inherited
-
FASECONEXION:
Inherited
-
VOLTAJE:
Inherited
-
POSICIONNORMAL_A:
Inherited
-
POSICIONNORMAL_B:
Inherited
-
POSICIONNORMAL_C:
Inherited
-
POSICIONACTUAL_A:
Inherited
-
POSICIONACTUAL_B:
Inherited
-
POSICIONACTUAL_C:
Inherited
-
INTERRUPTORBYPASS:
Inherited
-
INDICADORPOSICIONINTERRUPTOR:
Inherited
-
PARROQUIA:
Inherited
-
CORRIENTE:
Inherited
-
PROTECCION:
Inherited
-
CODIGOESTRUCTURA:
Coded Values:
[SPR0017: 1R400_95R]
,
[SPR0018: 1R400_125R]
,
[SPR0019: 1R600_95R]
, ...115 more...
-
CORRIENTEMAXCORTOCIRCUITO:
Inherited
-
TRANSFERENCIAACTIVO:
Inherited
-
TIPOUSO:
Inherited
-
CONTROL:
Inherited
ID: 5
Name: Celdas de Seccionamiento
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
ALIMENTADORID:
Inherited
-
ALIMENTADOR2ID:
Inherited
-
CODIGOEMPRESA:
Inherited
-
PROVINCIA:
Inherited
-
CANTON:
Inherited
-
FASECONEXION:
Inherited
-
VOLTAJE:
Inherited
-
POSICIONNORMAL_A:
Inherited
-
POSICIONNORMAL_B:
Inherited
-
POSICIONNORMAL_C:
Inherited
-
POSICIONACTUAL_A:
Inherited
-
POSICIONACTUAL_B:
Inherited
-
POSICIONACTUAL_C:
Inherited
-
INTERRUPTORBYPASS:
Inherited
-
INDICADORPOSICIONINTERRUPTOR:
Inherited
-
PARROQUIA:
Inherited
-
CORRIENTE:
Inherited
-
PROTECCION:
Inherited
-
CODIGOESTRUCTURA:
Coded Values:
[SSS0067: 3ES600_150S]
,
[SST0067: 3ES600_150T]
,
[SSV0067: 3ES600_150V]
-
SUBSOURCE:
Inherited
-
CORRIENTEMAXCORTOCIRCUITO:
Inherited
-
TRANSFERENCIAACTIVO:
Inherited
-
TIPOUSO:
Inherited
-
CONTROL:
Inherited
ID: 6
Name: Celdas de Interconexión
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
ALIMENTADORID:
Inherited
-
ALIMENTADOR2ID:
Inherited
-
CODIGOEMPRESA:
Inherited
-
PROVINCIA:
Inherited
-
CANTON:
Inherited
-
FASECONEXION:
Inherited
-
VOLTAJE:
Inherited
-
POSICIONNORMAL_A:
Inherited
-
POSICIONNORMAL_B:
Inherited
-
POSICIONNORMAL_C:
Inherited
-
POSICIONACTUAL_A:
Inherited
-
POSICIONACTUAL_B:
Inherited
-
POSICIONACTUAL_C:
Inherited
-
INTERRUPTORBYPASS:
Inherited
-
INDICADORPOSICIONINTERRUPTOR:
Inherited
-
PARROQUIA:
Inherited
-
CORRIENTE:
Inherited
-
PROTECCION:
Inherited
-
CODIGOESTRUCTURA:
Coded Values:
[SSS0069: 3EI600_150S]
,
[SST0069: 3EI600_150T]
,
[SSV0069: 3EI600_150V]
-
SUBSOURCE:
Inherited
-
CORRIENTEMAXCORTOCIRCUITO:
Inherited
-
TRANSFERENCIAACTIVO:
Inherited
-
TIPOUSO:
Inherited
-
CONTROL:
Inherited
ID: 7
Name: Celdas de Protección
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
ALIMENTADORID:
Inherited
-
ALIMENTADOR2ID:
Inherited
-
CODIGOEMPRESA:
Inherited
-
PROVINCIA:
Inherited
-
CANTON:
Inherited
-
FASECONEXION:
Inherited
-
VOLTAJE:
Inherited
-
POSICIONNORMAL_A:
Inherited
-
POSICIONNORMAL_B:
Inherited
-
POSICIONNORMAL_C:
Inherited
-
POSICIONACTUAL_A:
Inherited
-
POSICIONACTUAL_B:
Inherited
-
POSICIONACTUAL_C:
Inherited
-
INTERRUPTORBYPASS:
Inherited
-
INDICADORPOSICIONINTERRUPTOR:
Inherited
-
PARROQUIA:
Inherited
-
CORRIENTE:
Inherited
-
PROTECCION:
Inherited
-
CODIGOESTRUCTURA:
Coded Values:
[SSS0068: 3EP400_150S]
,
[SST0068: 3EP400_150T]
,
[SST0076: 3EP630_95T]
, ...1 more...
-
SUBSOURCE:
Inherited
-
CORRIENTEMAXCORTOCIRCUITO:
Inherited
-
TRANSFERENCIAACTIVO:
Inherited
-
TIPOUSO:
Inherited
-
CONTROL:
Inherited
ID: 8
Name: Interruptores Subterraneos
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
ALIMENTADORID:
Inherited
-
ALIMENTADOR2ID:
Inherited
-
CODIGOEMPRESA:
Inherited
-
PROVINCIA:
Inherited
-
CANTON:
Inherited
-
FASECONEXION:
Inherited
-
VOLTAJE:
Inherited
-
POSICIONNORMAL_A:
Inherited
-
POSICIONNORMAL_B:
Inherited
-
POSICIONNORMAL_C:
Inherited
-
POSICIONACTUAL_A:
Inherited
-
POSICIONACTUAL_B:
Inherited
-
POSICIONACTUAL_C:
Inherited
-
INTERRUPTORBYPASS:
Inherited
-
INDICADORPOSICIONINTERRUPTOR:
Inherited
-
PARROQUIA:
Inherited
-
CORRIENTE:
Inherited
-
PROTECCION:
Inherited
-
CODIGOESTRUCTURA:
Coded Values:
[SSS0061: 3I4_200S]
,
[SSS0062: 3I4_600S]
,
[SSS0063: 3I4_900S]
, ...15 more...
-
SUBSOURCE:
Inherited
-
CORRIENTEMAXCORTOCIRCUITO:
Inherited
-
TRANSFERENCIAACTIVO:
Inherited
-
TIPOUSO:
Inherited
-
CONTROL:
Inherited
ID: 9
Name: Controladores-MV
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
ALIMENTADORID:
Inherited
-
ALIMENTADOR2ID:
Inherited
-
CODIGOEMPRESA:
Inherited
-
PROVINCIA:
Inherited
-
CANTON:
Inherited
-
FASECONEXION:
Inherited
-
VOLTAJE:
Inherited
-
POSICIONNORMAL_A:
Inherited
-
POSICIONNORMAL_B:
Inherited
-
POSICIONNORMAL_C:
Inherited
-
POSICIONACTUAL_A:
Inherited
-
POSICIONACTUAL_B:
Inherited
-
POSICIONACTUAL_C:
Inherited
-
INTERRUPTORBYPASS:
Inherited
-
INDICADORPOSICIONINTERRUPTOR:
Inherited
-
PARROQUIA:
Inherited
-
CORRIENTE:
Inherited
-
PROTECCION:
Inherited
-
SUBSOURCE:
Inherited
-
CORRIENTEMAXCORTOCIRCUITO:
Inherited
-
TRANSFERENCIAACTIVO:
Inherited
-
TIPOUSO:
Inherited
-
CONTROL:
Inherited
Supported Operations:
Query
Query Attachments
Generate Renderer
Return Updates
Iteminfo
Thumbnail
Metadata